Customization: | Available |
---|---|
Type: | Operating Table |
Kind: | Orthopedics Gynecology Otolaryngology |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Table length | 2170±20mm |
Table width | 560±10mm (with side rails) 520±10mm (without side rails) |
Table lifting height | 540±20mm 1050±20mm |
Table lifting travel (electric) | 500±20mm |
Bed front tilt angle (electric) | Forward tilt ≥ 30° Backward tilt ≥ 30° |
Bed tilt angle (electric) | Left tilt ≥ 20° Right tilt ≥ 20° |
Headboard folding angle (manual) | Upward fold ≥45° Downward fold ≥90° Detachable |
Leg folding angle (manual) | Fold upwards ≥15° Fold downwards ≥90° Extension ≥90° Detachable |
Back panel folding angle (electric) | Upward fold ≥85° Downward fold ≥40° |
Built-in waist bridge travel | ≥120mm |
Maximum translation distance of table (electric) | ≥300mm |
Rated load | 250KG |
Functional description - Discover the comprehensive capabilities of the Mingxu Mx Table 8000, a masterpiece of advanced medical technology tailored to enhance surgical precision and efficiency.
1. Experience the unparalleled power of a full hydraulic control system, engineered for remarkable load-bearing capacity, whisper-quiet operation, and exceptional safety. Designed to seamlessly serve a diverse spectrum of surgeries across ophthalmology, neurosurgery, thoracic, abdominal, gynecology, urology, ENT, orthopedics, and beyond in esteemed medical facilities.
2. With cutting-edge microcomputer and dual-controller technology, safety is prioritized through a robust safety lock against misoperation. Featuring independent systems via a hand control box and auxiliary switch, the operating table remains fully functional even if one system encounters an issue.
3. The ingenious butterfly base allows effortless maneuverability for close-proximity procedures. Encased in SUS304 stainless steel, the robust construction resists corrosion, is simple to maintain, and ensures enduring durability. The stainless steel components promise unwavering strength and stability.
4. Designed with precision, the tabletop incorporates four dynamic sections: head board, back board, hip board, and split-type leg board, offering unparalleled adaptability.
All sections feature X-ray translucent materials, with an integrated X-ray film box layer beneath the bed board, facilitating seamless imaging capabilities.
5. With its modular design, detachable head and leg boards, and quick-connect devices, the table ensures supreme safety and surgical accuracy, meeting an array of surgical positioning needs.
6. The multi-layer memory foam mattress optimizes pressure distribution, preventing pressure-induced tissue damage during extended surgeries. This design minimizes bedsores, remains water-resistant, stain-proof, and is effortlessly cleanable and anti-static.
7. Featuring a state-of-the-art one-button reset, effortlessly return the table to its original horizontal position, streamlining surgical preparations.
8. The intuitive one-button flexion/anti-flexion capability simplifies achieving the lumbar bridge position for specialized surgical needs.
9. Boasting intelligent electric hydraulic brakes, stability is assured as the four-point base engages the ground during activation, providing steadfast reliability on any surface, flat or inclined.
Basic configuration list | |
Operating table bed | 1Set |
Mattress | 1Set |
Anesthesia screen | 1pc |
Armrest | 2pc |
Leg support | 2pc |
Body straps | 1set |
Square Slider | 3pc |
Hand control | 1pc |
Power cord | 1pc |
Product Certificate | 1set |
User Manual | 1set |
Q1: What is the working principle of the electro-hydraulic operating table?
A: The electrohydraulic operating table uses the motor to drive the work of the hydraulic system, sends the hydraulic oil into the hydraulic cylinder through the hydraulic pump, and uses the liquid pressure to move all parts of the operating table up and down, back and forth, left and right.
Q2: What are the safety measures of electro-hydraulic operating table?
A: There are many safety measures for the electro-hydraulic operating table, including automatic pressure relief device, emergency stop button, overload protection device, locking device and so on. When using the device, you must follow the operation rules in the user manual and pay attention to operation safety.
Q3: What are the precautions for the maintenance of electro-hydraulic operating table?
A: Precautions for the maintenance of electrohydraulic operating tables include: keeping clean, avoiding collisions with heavy objects, checking electrical appliances, hydraulic systems, pneumatic systems, and so on. Users can perform routine maintenance according to the requirements of the user manual, and seek professional technical services in time.
Q4: Does the electro-hydraulic operating table need regular maintenance?
A: Yes, the electrohydraulic operating table needs to be repaired and maintained regularly to ensure the normal operation and service life of the equipment. According to the use of the situation, we will generally give the corresponding maintenance cycle and way, the user can carry out maintenance, replacement parts and other work according to the requirements.